LED Double Tube Fixture
This Series LED tube light fixture(P2 Series ) was composed of waterproof PC housing and T8 led tubes, IP65 rating and anti-UV transparent diffuser with high light transmittance, Ideal product for replacing exsiting fluorescent tube lights fixtures. Avalible in 2FT 1X9w, 2x9w; 4FT 1x18w ,2x18w 5FT 1x22w ,2x22w. Standard and emergency function option. It can be widely used in tunnel, garage, underground passage, stair well, power distribution room, evacuation passage, parking lots .
- Finish Color : Milky(White) + Gray
- Mount Type: Suspension mounted, Wall or Ceiling Surface-Mounted
- Light Bulb Type: LED tubes
- Category: Hanging Lights, Emergency & Exit Lights, Waterproof Lights
- Brightness: 2000 – 6000 lumens
- Shade Material: Polycarbonate (PC)
- Style: LED Tri-proof Lights
- Decor Style: Modern
- Features: Indoor or Outdoor, Dimmable Sensor, Emergency Function
- Description
- Inquiry
Description
what is LED Double Tube Fixture
The LED Double Tube Fixture is a twin-T8 style linear luminaire for tough indoor and semi-outdoor applications. It combines high efficiency SMD2835 LEDs with an aluminum tube heat sink and PC base plus transparent UV resistant diffuser for even light output and long life. 2×9W, 2×18W and 2×22W options with 100-120 lm/W system efficacy — strong lumen output and energy savings for commercial spaces.
LED Double Tube Fixture Detail
Bridge wiring in fixture
no need to consider power-in direction
Bridge wiring inside the fixture provides a polarity-agnostic power path so installers don’t have to worry about tube orientation during installation. This simplifies wiring for long runs, reduces commissioning errors and speeds up installation for big projects.
Smart inverter for one tube in emergency mode
A compact smart inverter dedicated to one tube switches to battery power when mains fails, maintaining regulated light output in emergency mode. Intelligent control prioritizes efficient conversion and battery protection to prolong runtime and ensure predictable emergency performance.
Specifying fixtures with smart inverter avoids separate emergency drivers, simplifies wiring and ensures critical escape routes are lit in fault conditions.
Special housing for battery — quick replace design
A dedicated battery compartment with clip-fix or tool-free access allows for fast battery replacement without removing the whole fixture. This design minimizes maintenance downtime, perfect for big industrial lighting applications. It ensures battery replacement operations are quick, safe and traceable.
Contractors get standardized battery modules and clear access points; facility operators get lower lifetime maintenance costs and easier compliance with emergency system tests.
T8 LED tube with full PC cover & aluminum heatsink
A full polycarbonate (PC) cover with aluminum heatsink tube combines impact resistance and thermal management: PC diffuser resists UV aging and aluminum core draws heat away from the LED chip for longer life.
Anti-UV Transparent Diffuser
Durable PC Base
Metal Mounting Bracket
LED Double Tube Fixture Features(P2-Series)
- High-grade PC base and PC diffuser IP65/IK08 Rated.
- 2FT/4FT/5FT,Single/Double led tube and Stainless steel/PC clips option
- Single end power in,whole PC+AL heat sink led tube, more safety
- Bridge wiring in fitting, no need consider power direction of led tube
- Huge terminal block(hole size 5.0mm), safety and easy wiring
- Smart inverter for multi-function (option)
- Emergency function,battery with special housing for quick maintenance (option)
- Linkable connection function(option)
- Approved by CE ROHS SAA and C-Tick (RCM).
- 5 years warranty.
LED Double Tube Fixture PARAMETER DATA(P2-Series):
| Model | Input voltage | Watt | Sensor Dimming standby | Emergency |
| ZL-PTBLP9-2FT-CN | AC110V or 230V | 1*9w | x | x |
| ZL-PTBLP18-4FT-CN | AC110V or 230V | 1*18w | x | x |
| ZL-PTBLP22-5FT-CN | AC110V or 230V | 1*22w | x | x |
| ZL-PTBLP18-2FT-CN | AC110V or 230V | 2*9w | 100% / 20% /OFF | x |
| ZL-PTBLP36-4FT-CN | AC110V or 230V | 2*18w | 100% / 20% /OFF | x |
| ZL-PTBLP44-5FT-CN | AC110V or 230V | 2*22w | 100% / 20% /OFF | x |
| ZL-PTBLP9-2FT-CE | AC110V or 230V | 1*9w | x | >3hrs@3W |
| ZL-PTBLP18-4FT-CE | AC110V or 230V | 1*18w | x | >3hrs@3W |
| ZL-PTBLP22-5FT-CE | AC110V or 230V | 1*22w | x | >3hrs@3W |
| ZL-PTBLP18-2FT-CE | AC110V or 230V | 2*9w | 100% / 20% /OFF | >3hrs@3W |
| ZL-PTBLP36-4FT-CE | AC110V or 230V | 2*18w | 100% / 20% /OFF | >3hrs@3W |
| ZL-PTBLP44-5FT-CE | AC110V or 230V | 2*22w | 100% / 20% /OFF | >3hrs@3W |
| Note: x –No this function | ||||
LED Double Tube Fixture Specification(P2-Series):
| LUMINAIRE INFORMATION | ||||
| Model | ZL-T8YJF-2FT-D | ZL-T8YJF-4FT-D | ZL-T8YJF-5FT-D | |
| Rated Power(LED tube) | 2*9W | 2*18W | 2*22W | |
| Install | Surface Mount/Hanging/Linkable | |||
| Protection Rating | IP65 IK08 | |||
| Housing | Polycarbonate | |||
| Optics | Transparent Polycarbonate Diffuser | |||
| Operating Temperature | -20℃ to 40℃ / 0℃ to 40℃(Emergency) | |||
| Warranty | 3 Years | |||
| Dimming Option | Microwave Sensor – 3 Stepped Version(100%-20%-OFF) | |||
| Emergency Option | 3+ Hours Batteries Autonomy (Single Emergency LiFePO4 Battery) | |||
| PHOTOMETRIC | ||||
| Luminous Efficacy | 100-120lm/W | |||
| LED | SMD | |||
| CCT | 3000K/4000K/5000K/6000K | |||
| CRI | >80 | |||
| Beam Angle | 120 degree | |||
| ELECTRICAL | ||||
| Input power Supply | AC200-240V 50HZ/60Hz | |||
| Power Factor | 0.9 | |||
| Lifespan@Ta25°(L70) | 54,000 hours | |||
| Electrical Classification | Class I | |||
LED Double Tube Fixture Application:
|
|
|
Quick and easy maintenance replacement
Easy Maintenance LED Tube |
PC knob for quick fixing gear tray |
Huge terminal block for holding multiple wires |
Body with quick buckles |
Special housing for quick replace battery |
Plug and play connection |
Supply and Sales Range(Main Markets)
Americas EU Australia Middle East HK.
LED Double Tube Fixture size dimension:
Packing Specification:
LED Double Tube Fixture Installation methods:
Our Competitive Advantages:
1. ODM/OEM services available; samples provided; customization options for brand and function.
2. COMLED Technology is a leading provider of emergency Workshop Vapor Tight Lighting solutions, with a decade of expertise in designing, manufacturing, and selling Workshop Vapor Tight Light.
3. Factory area: 2,000 m²; Production capacity: 30,000 units per month.
4. All LED fixtures undergo rigorous quality control.
5. Our Workshop Vapor Tight Light are certified CE, SAA, LCP, ISTMT, and TM21, and meet regional electrical codes and safety standards.
Conclusion
The LED Double Tube Fixture is a twin-T8 style linear luminaire for tough indoor and semi-outdoor applications. It combines high efficiency SMD2835 LEDs with an aluminum tube heat sink and PC base plus transparent UV resistant diffuser for even light output and long life. 2×9W, 2×18W and 2×22W options with 100-120 lm/W system efficacy — strong lumen output and energy savings for commercial spaces.
Frequently Asked Questions
What wattage and lumen output can I expect from the LED Double Tube Fixture and how many do I need?
- Wattages: 2×9W, 2×18W, 2×22W.
- Efficacy: 100–120 lm/W. To calculate lumen output, multiply fixture wattage by efficacy range. Example (2×18W = 36W): 36W × 100–120 lm/W ≈ 3,600–4,320 lumens per fixture.
- How many to install: determine target lux for the space (e.g., 100–200 lux for general storage, 300+ lux for task zones), measure area (m²), then divide total lumens required by lumens per fixture. For help sizing a run or achieving uniformity in corridors or tunnels, COMLED’s technical team can provide layout guidance and recommended spacing.
Can this fixture be used in wet or dusty environments such as parking garages or tunnels?
Yes. The IP65 rating means dust-proof and low-pressure water jets, so it’s suitable for covered parking, tunnels and similar semi-exposed areas. IK08 impact resistance adds mechanical durability against knocks or stone chips. The transparent PC diffuser has anti-UV treatment to preserve transmission over time. For fully exposed outdoor installations or areas with chemicals or pressurized washdown, check with COMLED to confirm the right variant and mounting method.
What does “single-end power-in” mean and are there installation risks?
“Single-end power-in” means the power supply is at one end of the tube assembly, not both ends. The advantage is easier retrofitting where the power is already at one end; it’s also faster installation. But correct wiring is crucial: follow local electrical code and the fixture wiring diagram. For on-site wiring recommendations, compatible linkable wiring schemes or to request a version with different wiring, contact COMLED’s technical/after-sales support for drawings and guidance.
Is there an emergency option and what is the warranty?
An emergency version is available to meet egress and safety lighting requirements; please request emergency-spec details when ordering (COMLED can provide the emergency runtime and battery option that suits your project). The standard non-emergency product warranty is 3 years. For emergency variants, battery and driver warranties may follow manufacturer terms — confirm battery life and warranty specifics when ordering.
How does this simplify bulk purchasing and installation in large projects?
- Standard sizes & terminals: T8 footprint and 5.0mm push-in terminals means faster installation and less electrician time.
- Mounting & durability: stainless/PC clips and IP65/IK08 rating means less rework and replacement.
- Factory customization: linkable runs and emergency versions means you can standardize across a site.
- Support: COMLED can provide technical documentation and sales support to help with order quantities, packaging and delivery terms for large orders—ideal for contractors and facilities teams who want predictable lead times and consistent performance.




















Packing Specification:



